Prove fault-finding and testing

Fault finding and testing are skills built only by doing. This range lets learners create, find and test real faults safely and repeatably, from installation testing and safe isolation through to motor faults, building the diagnostic competence employers expect on day one. Because the supply is limited to extra-low voltage, learners can get it wrong, work out why, and try again without risk.

Performance coverage by unit of competency

The table below shows the Performance coverage, the practical that our equipment lets a learner demonstrate against each unit of competency.

Unit of competency Unit name Infinispark product Performance
UEEEL0039
Design, install and verify compliance and functionality of general electrical installations
Installation Testing Faultboard
51%
UEEEL0014
Isolate, test and troubleshoot low voltage electrical circuits
Motor Faults Pracbox and Installation Testing Faultboard
75%
UEEEL0024
Single & three-phase machines (motors)
Motor Faults Pracbox
99%

Why it matters

Diagnostic skill is the hardest thing to assess fairly and the easiest to fake on paper. Because faults are introduced on a controlled unit, every learner is assessed against the same conditions, and a trainer can move from teaching to assessment without rebuilding a setup. Learners leave able to isolate safely, test to standard and find a fault under pressure.

“With the Infinispark Installation Testing Faultboards, we love the fact that we can open the door at the back of the testing board, can go through and do our testing selections depending on what level, depending on what difficulty level we want to go to. And it’s as easy as that.”

– Jarrod Brennan, Lead Educator, Bendigo Kangan Institute

Our Solutions

Installation Faults Pracbox

Do you train apprentices in mandatory testing and safe isolation? The Installation Faults Pracbox provides 31 fault sets of varying difficulty, with one to three faults present at a time, helping learners develop a systematic approach to fault-finding. A built-in 24V AC supply supports extra-low voltage isolation practice, while separate fault and isolation modes keep exercises controlled. With simple switch-operated fault selection and a portable design, it makes practical training easy to organise in the classroom or workshop.

Installation Testing Faultboard

Preparing learners for installation testing, fault-finding or Licensed Electricians Assessments? The Installation Testing Faultboard offers up to 100 testing opportunities with changing faults, helping learners build diagnostic skills through repeated practice. Battery power and an onboard touchscreen make fault selection straightforward without external devices or software. Designed for UEEEL0039 and UEEEL0014, it supports practical training and assessment while saving trainers the time and cost of building their own testing equipment.

Motor Faults Pracbox​

How many pieces of equipment do you need to teach single and three-phase induction motors and their fault-finding? Not many, with the Motor Faults Pracbox. It includes a single-phase motor, a three-phase motor (both ELV) and a powerful fault system that replaces at least 10 separate items for subjects like UEEEL0024. It also gamifies fault-finding, lifting learner engagement and trainer productivity while supporting the practical requirements of relevant units of competency.

Find the Right Equipment for Fault-Finding and Testing

Want to learn more about our fault-finding and testing equipment and how it can support your electrical training? Contact our team to explore the range, discuss your classroom and assessment requirements, and find the right equipment to help learners develop practical skills in fault-finding, installation testing and safe isolation. Whether you need detailed product information, a demonstration, or a quote, we’re here to answer your questions and help you choose equipment that suits your training needs.

Frequently Asked Questions

Infinispark’s Fault Finding and Testing range helps learners develop essential skills in electrical testing, safe isolation, fault identification and systematic troubleshooting. Through hands-on activities, learners can practise diagnosing faults in electrical installations, circuits and motors. The equipment encourages a structured approach to problem-solving, helping users develop the practical skills and confidence needed to identify and resolve electrical faults.

Infinispark’s fault-finding equipment incorporates controlled fault scenarios that allow learners to investigate and diagnose electrical problems using appropriate testing procedures. Trainers can introduce different faults, enabling learners to practise identifying the cause of a problem and determining the appropriate corrective action. These repeatable exercises help bridge the gap between theoretical knowledge and practical troubleshooting in real-world electrical environments.

Safety is a key consideration in the design of Infinispark’s fault-finding equipment. The range uses Extra Low Voltage (ELV) systems to provide a controlled environment where learners can practise testing, fault identification and isolation procedures without exposure to the electrical risks associated with conventional low-voltage training systems. This allows learners to build confidence and develop safe working practices before applying their skills in operational environments.

Yes. Infinispark’s fault-finding equipment supports practical assessment and skills verification by providing controlled, repeatable fault scenarios. Trainers and assessors can observe how learners approach testing, apply diagnostic procedures and identify faults under consistent conditions. This makes the equipment suitable for nationally recognised training and assessment, as well as industry-based skills development and competency verification programs.

Traditional fault-finding exercises often require trainers to build circuits, introduce faults manually and reset equipment between activities. Infinispark’s purpose-built systems simplify this process by incorporating selectable faults and testing scenarios into ready-to-use equipment. This reduces setup time, provides consistent training conditions and allows trainers to focus more on developing learners’ practical troubleshooting skills.

Yes. In addition to supporting apprenticeship training and nationally recognised qualifications, Infinispark’s fault-finding equipment can be used by electrical contractors, mining companies and other industries to develop and refresh employees’ diagnostic skills. It provides opportunities for apprentices and experienced workers to practise systematic fault-finding, strengthen their technical knowledge and improve their confidence in identifying electrical problems.