Electrical Installation Testing Faultboard

An electrical fault training board for apprentice and licensed electrician assessments.

The Electrical Installation Testing Faultboard is a portable, Australian-made unit for practising and assessing mandatory installation tests. 

It covers insulation resistance, continuity of the earthing system, polarity and fault finding, all mapped to AS/NZS 3000. Built in Australia, the electrical fault-finding training board lets learners and electricians create, find and test real faults safely and repeatably.

Electrical Installation Testing Faultboard: Training Videos and Resources

Watch our training video to get started with the fault-finding training board, plus virtual training so you get the most out of the Installation Testing Faultboard. 

Video Demonstration

Key features

01

50 fault sets

The components inside satisfy the majority of the practical assessment requirements of the relevant units of competency. As a built-in electrical fault simulator, our electrical assessment equipment keeps compliance for registration and audits easy to maintain.

02

Ready to use

Built specifically for installation testing, so trainers don’t spend weekends designing and constructing a board from scratch. It arrives ready to run.

 

03

No Power Point Needed

Able to operate for up to 40 hours on a full battery charge and can recharge in two hours. Its portable, battery-operated design allows for flexibility across classrooms, workshops and training facilities.

Units of competency

Unit Code Unit Name
UEENEEG105A
Verify compliance and functionality of low voltage general electrical installations
UEENEEG108A
Trouble-shoot and repair faults in low voltage electrical apparatus and circuits
UEEEL0039
Design, install and verify compliance and functionality of general electrical installations
UEEEL0014
Isolate, test and troubleshoot low voltage electrical circuits

Benefits

Learners become test experts

Changing fault conditions across 50 sets means learners repeat the tests until testing becomes automatic, which is what builds both confidence and competence.

 

Increase Trainer Productivity

Trainers spend their time delivering training and assessment, rather than building, maintaining and redesigning practical equipment every time a cohort starts.

 

Cost reduction

A purpose-built electrical training board costs less than a custom one. Development, labour and components are all accounted for, and it’s ready to use on day one.

Technical specifications

Parameter Value Purpose & benefit
Operating Voltage
Battery-operated fault control system with onboard charger
Allows the Faultboard to operate without a continuous mains power connection, providing flexibility across classrooms, workshops and training facilities.
Run Time
Up to 40 hours on a full charge
Provides extended operating time between charges, reducing interruptions during practical training and assessment sessions.
Charge Time
Approximately 2 hours, with pass-through charging
Allows the Faultboard to be operated while charging, minimising downtime between training sessions.
Product Size
Aluminium profile stand with heavy-duty wheels 1200mm x 750mm x 1670mm
Good size for practising testing at standing height. Nice finish and robust
Fault control access
Onboard touchscreen located within a lockable compartment.
Allows trainers and assessors to select and manage fault scenarios while restricting learner access to the controls.
Number of concurrent faults
Faults 1 to 10 – One Fault, Faults 11 to 20 – Two Faults, Faults 21 to 30 – Three Faults, Faults 31 to 40 – Four Faults & Faults 41 to 50 – Five or more Faults
Faults increase in complexity to increase learner engagement.
Training resources
Training videos available on our Learning Platform plus virtual training
Get the most out of the Electrical Installation Testing Faultboard
Australian Made

Australian made & trainer designed

The Electrical Installation Testing Faultboard is an Australian-made installation test board for IR, continuity, polarity and fault finding, mapped to AS/NZS 3000.Compliance couldn’t be easier!

Frequently Asked Questions

The Electrical Installation Testing Faultboard is designed to allow learners to practise essential installation testing procedures without requiring the socket outlets and loads to be energised. This includes insulation resistance, continuity of the earthing system, polarity and fault identification.
 
The equipment provides a controlled environment for developing practical testing skills and conducting assessments without the need for a live electrical installation. If your training requirements include energising socket outlets or loads, please contact our team to discuss your specific needs and whether a suitable solution is available.

The Electrical Installation Testing Faultboard includes 50 predetermined fault sets, with varying levels of complexity. Only one fault set can be activated at a time, but each set may contain multiple faults for learners to identify and diagnose.

The fault sets are arranged progressively, allowing trainers to introduce more challenging scenarios as learners develop their testing and troubleshooting skills. Each set has been carefully designed to ensure the faults work together without creating unintended fault conditions. This provides consistent, repeatable testing scenarios for both practical training and assessment.

The Electrical Installation Testing Faultboard is supplied with a booklet containing test sheets and details of the predetermined fault sets. These resources allow trainers and assessors to identify the faults associated with each scenario and use the information to guide practical training, assess learner performance or discuss test results.
 
The booklet is also available through Infinispark’s Learning Platform, providing convenient ongoing access to the documentation whenever required.
Yes. The fault controls are housed within a secure, lockable compartment at the rear of the Electrical Installation Testing Faultboard. This allows trainers and assessors to select the required fault scenario and restrict learner access to the controls during practical exercises or assessments.
By preventing learners from viewing or changing the selected faults, trainers can maintain consistent assessment conditions and evaluate each learner’s ability to follow appropriate testing procedures, interpret results and identify faults independently.

 

No. The Electrical Installation Testing Faultboard features a rechargeable battery operated fault control system, allowing it to be used without a continuous mains power connection. A full charge provides up to 40 hours of operation, and the onboard charger allows the equipment to be used while charging. This makes the Faultboard suitable for practical training and assessment across different classrooms, workshops and training facilities without relying on a nearby power outlet.